Skip to main content

Encoder | INDUCTIVE Rotary | IND-MAX-200

INDUCTIVE MAX Encoder : For Extreme Conditions

image of Encoder IND-ROT-096-A21

IND-MAX inductive angle encoders provide robust, high-precision measurement in extreme environment applications across land, sea, and air.


Engineered for real-time applications, IND-MAX encoders deliver superior position and speed sensing in the harshest environments. Unlike optical and capacitive technologies, which can become unreliable in harsh conditions, the IND-MAX encoder series is designed to deliver superior performance and durability, exceeding the limits of existing technologies. IND-MAX encoders are available in sizes up to 375mm in diameter, feature a compact, low-profile design with a large bore and up to 23-bit resolution. Their robust housing and wide operating temperature range ensure high reliability even in harsh, high-shock environments.

Advantages

  • Plug-n-play
  • No field calibration required
  • Wide mounting tolerances
  • High accuracy

Benefits

  • Low installation cost
  • Low integration effort
  • Easy installation

System Data

IND-MAX-200
TypeAxial, frameless, true absolute, inductive measuring principle
Standard Resolution23 bits
ENOB in entire mounting tolerance range22 bits
High AccuracyEnhanced accuracy can be achieved depending on the mounting setup
Standard Accuracy± 007“,± 0.002°,± 035 µrad
Thickness10.95
Hysteresisnone
Repeatability1 resolution count
Position update rate and signal latencyReal-time
Power-up Timemax. 0.8 sec

Electrical Data

Supply voltagemin.4.35Vdc.max.36Vdc
Reverse polarity protectionyes
Current Consumptionmax. 150 mA @ 5 Vdc max. 50 mA @ 24 Vdc

Mechanical Data

Stator Base MaterialAnodized aluminum CTE ~ 24 ppm/°C
Stator Weight225.00 g
Rotor Base MaterialAnodized aluminum CTE ~ 24 ppm/°C
Rotor Weight140.00 g
VibrationEN 60068-2-6, 20 g, 55 .. 2000 Hz
ShockEN 60068-2-27, 200 g, 6 ms

Mounting Tolerances

Nominal Axial (air-gap)0.50 mm
Axial Tolerance0.30 mm (0.20 mm to 0.80 mm)
Radial Tolerances0.20 mm

Environmental Data

Temperature Range - Standard Operating-20°C .. +85°C
Temperature Range - Standard Storage-20°C .. +85°C
Temperature Range - Extended Operating-40°C .. +105°C
Temperature Range - Extended Storage-55°C .. +125°C
Ingress ProtectionIP67
EMC Immunitycomplies with EN IEC 61000-6-2
EMC Emissioncomplies with EN IEC 61000-6-4